lx
2025-08-04 e0279fe6db39d1071ef04ad0080b887cb6a0d335
ErrorAnalysis.Service/COMergeCalcService.cs
@@ -22,52 +22,78 @@
        const int _oWinStartIndex = (int)(4.88 / _gg + _offset); // org
        const int _oWinEndIndex = (int)(6.36 / _gg + _offset); // width = 6.36-4.88=1.48
        private static double GetFarInterplolateResult(string modelId, double porosity, double sw, int readSw, double speed, double depth)
        {
            double result = 0;
            var cResult = RepositoryInstance.Instance.COFarResultRepository?.GetCOFarResult(modelId, (int)porosity, readSw);
            if (cResult == null)
                throw new InvalidDataException("COFarResult not found");
            var cArr = cResult.InelasticSpec?.Split(',').Select(v => Convert.ToDouble(v)).ToArray();
            if (cArr == null)
                throw new InvalidDataException("COFarResult InelasticSpec is null");
        const double _coef = 1e8 * 2.54 * 2.54 * 4 * 6 * 2 * 11 * 77 * 0.2 / 0.6;
            var length = readSw == 0 ? _cWinEndIndex - _cWinStartIndex + 1 : _oWinEndIndex - _oWinStartIndex + 1;
            var originC = cArr.Skip(readSw == 0 ? _cWinStartIndex : _oWinStartIndex).Take(length).Sum();
            var coef = originC * 1e8 * 2.54 * 2.54 * 4 * 6 * 2 * 11 * 77 * 0.2 / 0.6 / speed * depth * 0.07;
            result = coef;
            if (sw > 0 && sw < 100)
        private static (double, double) GetFarInterplolateResult(string modelId, double porosity, double sw, double speed, double depth)
        {
            var cWinLength = _cWinEndIndex - _cWinStartIndex + 1;
            var oWinLength = _oWinEndIndex - _oWinStartIndex + 1;
            var oilLine = RepositoryInstance.Instance.COFarResultRepository?.GetCOFarResult(modelId, (int)porosity, 0);
            var waterLine = RepositoryInstance.Instance.COFarResultRepository?.GetCOFarResult(modelId, (int)porosity, 100);
            if (oilLine == null || waterLine == null)
                throw new InvalidDataException("COFarResult Line is null");
            var oilLineValArr = oilLine.InelasticSpec.Split(',').Select(v => Convert.ToDouble(v)).ToArray();
            var waterLineValArr = waterLine.InelasticSpec.Split(',').Select(v => Convert.ToDouble(v)).ToArray();
            var oilLineC = oilLineValArr.Skip(_cWinStartIndex).Take(cWinLength).Sum() * _coef / speed * depth * 0.07;
            var oilLineO = oilLineValArr.Skip(_oWinStartIndex).Take(oWinLength).Sum() * _coef / speed * depth * 0.07;
            var waterLineC = waterLineValArr.Skip(_cWinStartIndex).Take(cWinLength).Sum() * _coef / speed * depth * 0.07;
            var waterLineO = waterLineValArr.Skip(_oWinStartIndex).Take(oWinLength).Sum() * _coef / speed * depth * 0.07;
            double cRes = 0, oRes = 0;
            if (sw == 0)
            {
                if (readSw == 0)
                    result = Utility.Interpolate(sw, 100, 0, 0, coef);
                else
                    result = Utility.Interpolate(sw, 0, 0, 100, coef);
                cRes = waterLineC;
                oRes = waterLineO;
            }
            return result;
            else if (sw == 100)
            {
                cRes = waterLineC;
                oRes = waterLineO;
            }
            else if (sw > 0 && sw < 100)
            {
                cRes = Utility.Interpolate(sw, 100, waterLineC, 0, oilLineC);
                oRes = Utility.Interpolate(sw, 0, oilLineO, 100, waterLineO);
            }
            return (cRes, oRes);
        }
        private static double GetNearInterplolateResult(string modelId, double porosity, double sw, int readSw, double speed, double depth)
        private static (double, double) GetNearInterplolateResult(string modelId, double porosity, double sw, double speed, double depth)
        {
            double result = 0;
            var cResult = RepositoryInstance.Instance.CONearResultRepository?.GetCONearResult(modelId, (int)porosity, readSw);
            if (cResult == null)
                throw new InvalidDataException("CONearResult not found");
            var cArr = cResult.InelasticSpec?.Split(',').Select(v => Convert.ToDouble(v)).ToArray();
            if (cArr == null)
                throw new InvalidDataException("CONearResult InelasticSpec is null");
            var cWinLength = _cWinEndIndex - _cWinStartIndex + 1;
            var oWinLength = _oWinEndIndex - _oWinStartIndex + 1;
            var oilLine = RepositoryInstance.Instance.CONearResultRepository?.GetCONearResult(modelId, (int)porosity, 0);
            var waterLine = RepositoryInstance.Instance.CONearResultRepository?.GetCONearResult(modelId, (int)porosity, 100);
            if (oilLine == null || waterLine == null)
                throw new InvalidDataException("COFarResult Line is null");
            var oilLineValArr = oilLine.InelasticSpec.Split(',').Select(v => Convert.ToDouble(v)).ToArray();
            var waterLineValArr = waterLine.InelasticSpec.Split(',').Select(v => Convert.ToDouble(v)).ToArray();
            var length = readSw == 0 ? _cWinEndIndex - _cWinStartIndex + 1 : _oWinEndIndex - _oWinStartIndex + 1;
            var originC = cArr.Skip(readSw == 0 ? _cWinStartIndex : _oWinStartIndex).Take(length).Sum();
            var coef = originC * 1e8 * 2.54 * 2.54 * 2 * 6 * 11 * 2 * 77 * 0.2 / 0.6 * speed * depth * 0.07;
            result = coef;
            if (sw > 0 && sw < 100)
            var oilLineC = oilLineValArr.Skip(_cWinStartIndex).Take(cWinLength).Sum() * _coef / speed * depth * 0.07;
            var oilLineO = oilLineValArr.Skip(_oWinStartIndex).Take(oWinLength).Sum() * _coef / speed * depth * 0.07;
            var waterLineC = waterLineValArr.Skip(_cWinStartIndex).Take(cWinLength).Sum() * _coef / speed * depth * 0.07;
            var waterLineO = waterLineValArr.Skip(_oWinStartIndex).Take(oWinLength).Sum() * _coef / speed * depth * 0.07;
            double cRes = 0, oRes = 0;
            if (sw == 0)
            {
                if (readSw == 0)
                    result = Utility.Interpolate(sw, 100, 0, 0, coef);
                else
                    result = Utility.Interpolate(sw, 0, 0, 100, coef);
                cRes = waterLineC;
                oRes = waterLineO;
            }
            return result;
            else if (sw == 100)
            {
                cRes = waterLineC;
                oRes = waterLineO;
            }
            else if (sw > 0 && sw < 100)
            {
                cRes = Utility.Interpolate(sw, 100, waterLineC, 0, oilLineC);
                oRes = Utility.Interpolate(sw, 0, oilLineO, 100, waterLineO);
            }
            return (cRes, oRes);
        }
        /// <summary>
@@ -80,30 +106,28 @@
        /// <param name="readSw">读取含水饱和度(0为碳,100为氧)</param>
        /// <param name="speed">测速</param>
        /// <param name="depth">深度</param>
        /// <returns>碳或氧值</returns>
        /// <returns>碳和氧值</returns>
        /// <exception cref="InvalidDataException">孔隙度超过范围</exception>
        public static double GetFarMergeCOResult(string modelId, double porosity, double sw, int readSw, double speed, double depth)
        public static (double, double) GetFarMergeCOResult(string modelId, double porosity, double sw, double speed, double depth)
        {
            if (porosity > 40)
                throw new InvalidDataException("Porosity value out of range!");
            double result = 0;
            (double, double) result = (0, 0);
            if (porosity % 5 == 0)
            {
                result = GetFarInterplolateResult(modelId, porosity, sw, readSw, speed, depth);
                result = GetFarInterplolateResult(modelId, porosity, sw, speed, depth);
            }
            else
            {
                double ceilingResult = 0;
                var ceilingPorosity = Math.Ceiling(porosity / 5) * 5;
                ceilingResult = GetFarInterplolateResult(modelId, ceilingPorosity, sw, readSw, speed, depth);
                var ceilingResult = GetFarInterplolateResult(modelId, ceilingPorosity, sw, speed, depth);
                double floorResult = 0;
                var floorPorosity = Math.Floor(porosity / 5) * 5;
                floorResult = GetFarInterplolateResult(modelId, floorPorosity, sw, readSw, speed, depth);
                var floorResult = GetFarInterplolateResult(modelId, floorPorosity, sw, speed, depth);
                result = Utility.Interpolate(porosity, floorPorosity, floorResult, ceilingPorosity, ceilingResult);
                result.Item1 = Utility.Interpolate(porosity, floorPorosity, floorResult.Item1, ceilingPorosity, ceilingResult.Item1);
                result.Item2 = Utility.Interpolate(porosity, floorPorosity, floorResult.Item2, ceilingPorosity, ceilingResult.Item2);
            }
            return result;
        }
@@ -120,28 +144,26 @@
        /// <param name="depth">深度</param>
        /// <returns>碳或氧值</returns>
        /// <exception cref="InvalidDataException">孔隙度超过范围</exception>
        public static double GetNearMergeCOResult(string modelId, double porosity, double sw, int readSw, double speed, double depth)
        public static (double, double) GetNearMergeCOResult(string modelId, double porosity, double sw, double speed, double depth)
        {
            if (porosity > 40)
                throw new InvalidDataException("Porosity value out of range!");
            double result = 0;
            (double, double) result = (0, 0);
            if (porosity % 5 == 0)
            {
                result = GetNearInterplolateResult(modelId, porosity, sw, readSw, speed, depth);
                result = GetNearInterplolateResult(modelId, porosity, sw, speed, depth);
            }
            else
            {
                double ceilingResult = 0;
                var ceilingPorosity = Math.Ceiling(porosity / 5) * 5;
                ceilingResult = GetNearInterplolateResult(modelId, ceilingPorosity, sw, readSw, speed, depth);
                var ceilingResult = GetNearInterplolateResult(modelId, ceilingPorosity, sw, speed, depth);
                double floorResult = 0;
                var floorPorosity = Math.Floor(porosity / 5) * 5;
                floorResult = GetNearInterplolateResult(modelId, floorPorosity, sw, readSw, speed, depth);
                var floorResult = GetNearInterplolateResult(modelId, floorPorosity, sw, speed, depth);
                result = Utility.Interpolate(porosity, floorPorosity, floorResult, ceilingPorosity, ceilingResult);
                result.Item1 = Utility.Interpolate(porosity, floorPorosity, floorResult.Item1, ceilingPorosity, ceilingResult.Item1);
                result.Item2 = Utility.Interpolate(porosity, floorPorosity, floorResult.Item2, ceilingPorosity, ceilingResult.Item2);
            }
            return result;
        }